WHAT IS A CLEAN ROOM?

As the name suggests, a ‘clean room’ is clean and has low levels of pollutants such as dust, microbes, aerosol particles, and chemical vapours. It is a ‘contained space’ where provisions are made to minimize the introduction, generation, and retention of particles inside the room, and control other environmental parameters such as temperature, humidity and pressure.

Why is a Clean Room Environment important?

Certain industrial products are sensitive to particulates and get contaminated or destroyed in contact with pollutants, for example; medicinal/pharmaceutical products, semiconductor or electronic products, medical devices. Upcoming industries, such as nanotechnology and artificial intelligence (AI), also require clean room conditions.

 

Classification:

Depending on the level of contamination control required, clean rooms are classified by the International Standards Organisation (ISO) or British Standards (BS). It is based on the number and size of particles permitted per volume of air, classified from ISO Class 1 to 9.

The lower the ISO Class Number (i.e. the lower the size & concentration of the particles), the ‘cleaner’ the space.

table for clean room installation
 

To put this in perspective;

The ambient air outside in a typical city environment contains 35,000,000 particles per cubic metre, 0.5 micron and larger in diameter. This corresponds to an ISO Class 9 clean room which is at the lowest level of clean room standards.

An ISO Class 5 lab can not have more than 3,520 particles per cubic metre, 0.5 micron and larger in diameter.

In the UK, BS EN ISO 14644-1:2015 covers the requirements for classified clean environments and guidelines related to air cleanliness, looking specifically at particle concentration.

Air Handling & Ventilation:

To achieve the required contamination control, both air handling and filtration are important.

The particle size is controlled by the High Efficiency Particulate Air (HEPA) filter that is used to trap particles that are 0.3 micron and larger in size (ISO Class 2-9). For lower particle size Ultra Low Particulate Air (ULPA) (ISO Class 1) filters are used. All the air delivered to a clean room passes through HEPA filters.

Depending upon the ISO class desired, airflow type, airflow velocity and air changes are determined by always keeping positive pressure in the clean room.

clean room installation relative scale
 

Clean Room Design & Operation:

Many factors besides airborne particulate cleanliness must be considered in the design, specification, operation, and control of clean rooms and other controlled environments.

Personnel selected to work in clean rooms are required to undergo extensive training in contamination control theory. They enter and exit the cleanroom through airlocks, air showers and/or gowning rooms, and they must wear special clothing designed to trap contaminants that are naturally generated by the skin and body.

Bulb Laboratories work with specialist clean room suppliers to provide customised solutions to meet clients’ exact requirements. Together we design and then deliver the bespoke solution including validation and certification to meet the regulatory compliance.

Manisha Kulkarni
This email address is being protected from spambots. You need JavaScript enabled to view it.
07825332406

What's happening at Bulb Laboratories?

Find out more about us and what we can do for you, or read more articles like this.

About us What we do News & Blog

Get in Touch

If you are planning a new laboratory, refurbishing an existing one or have any questions, we’d love to hear from you.

Email

This email address is being protected from spambots. You need JavaScript enabled to view it.

 

CONNECT WITH US